📂 Kategori
Electrical & lighting
Alvorlig risiko
🇫🇷
løst
Watt and Co Nomade — Convertisseur 12V – 230V - 150W / USB
Type: Electric shock
Fare: The creepage and clearance distances between the windings are too small. The sol…
for 10 år siden
Se mere →
Alvorlig risiko
🇨🇾
🇬🇷
🇭🇷
🇭🇺
🇮🇪
løst
IKEA — Patrull
Type: Electric shock
Fare: When removing the light from the mains socket, the coloured plastic dome cover m…
for 10 år siden
Se mere →
Alvorlig risiko
🇫🇮
løst
Scan Lamps — Veggllampa
Type: Electric shock
Fare: The cable anchorage is not sufficient for efficient protection against pulling.…
for 10 år siden
Se mere →
Alvorlig risiko
🇱🇹
løst
KAXIGE — Unknown
Type: Electric shock, Fire
Fare: The electric resistance is insufficient which could lead to the user getting an…
for 10 år siden
Se mere →
Alvorlig risiko
🇱🇹
løst
BIERSIN — Przedluzacz (extension lead)
Type: Electric shock
Fare: The wires are too thin and the insulation can break exposing the live cores whic…
for 10 år siden
Se mere →
Alvorlig risiko
🇲🇹
🇨🇾
🇩🇰
🇫🇷
🇮🇪
løst
NVIDIA — SHIELD Tablet
Type: Fire
Fare: Due to thermal runaway, the battery can overheat which can lead to a fire.
T…
for 10 år siden
Se mere →
Alvorlig risiko
🇱🇻
løst
Huan Qiu — Unknown
Type: Electric shock
Fare: The cable attached to the flashing unit does not have sufficient mechanical stre…
for 10 år siden
Se mere →
Alvorlig risiko
🇩🇪
🇪🇸
løst
Brunner — Con-Cube 150, Universal Travel Adapter
Type: Electric shock
Fare: Live parts can be touched by the user during operation.
The product does not…
for 10 år siden
Se mere →
Alvorlig risiko
🇫🇷
løst
DECOLAC — Unknown
Type: Electric shock
Fare: The strain relief device on the power cable is inadequate which could lead to li…
for 10 år siden
Se mere →
Mellem risiko
🇬🇧
🇮🇪
løst
Wikes / Homebase / GET / ARGOS — Portable Dehumidifier
Type: Fire
Fare: A defective capacitor inside the dehumidifier may result in overheating and fire…
for 10 år siden
Se mere →
Alvorlig risiko
🇪🇸
løst
Fe Star — Tubo LED
Type: Electric shock
Fare: The control unit is not sufficiently resistant to impacts and live parts could c…
for 10 år siden
Se mere →
Alvorlig risiko
🇨🇿
løst
Cluster lights Indoor
Type: Electric shock
Fare: The cables are not securely attached to the controller and could detach exposing…
for 10 år siden
Se mere →
Alvorlig risiko
🇪🇸
🇫🇷
løst
Primera — Lampara Portatil
Type: Electric shock
Fare: When a lamp is inserted into the socket of the lamp holder, the live cap of the…
for 10 år siden
Se mere →
Mellem risiko
🇪🇸
🇫🇷
løst
Auchan — Fer à Repasser
Type: Chemical
Fare: In the case of a short circuit, the appliance gives off large quantities of smok…
for 10 år siden
Se mere →
Alvorlig risiko
🇬🇧
🇦🇹
🇩🇰
🇪🇸
🇫🇮
løst
Kenwood — BLEND-X PRO
Type: Cuts, Injuries
Fare: There is the potential for the lower blade to break and this can result in a lac…
for 10 år siden
Se mere →
Alvorlig risiko
🇪🇸
løst
SOKANY — Secador de Cabelos Portátil - Travel 4
Type: Fire
Fare: The cable is too thin and overheats which could cause a fire. Additionally, the…
for 10 år siden
Se mere →
Alvorlig risiko
🇫🇮
løst
Blight — LED Stripe, LED Downlight
Type: Electric shock
Fare: The power supply units supplied with the LED lights pose a risk of electric shoc…
for 10 år siden
Se mere →
Alvorlig risiko
🇫🇷
løst
Table Lamp
Type: Electric shock
Fare: The switch cover and the lampholder can both be loosened by hand, leading to liv…
for 10 år siden
Se mere →
Alvorlig risiko
🇫🇷
løst
ADDEX — Unknown
Type: Electric shock
Fare: There is insufficient clearance between the primary and secondary circuits. This…
for 10 år siden
Se mere →
Alvorlig risiko
🇫🇷
løst
STK — Quantum Travel Charger
Type: Fire
Fare: A conductor could be pinched between a component and the housing. This could lea…
for 10 år siden
Se mere →
Alvorlig risiko
🇫🇮
løst
Erä Trekking — Tehokas Erä Trekking 230 Otsalamppu
Type: Electric shock
Fare: The creepage distances between the primary and secondary windings in the power s…
for 10 år siden
Se mere →
Alvorlig risiko
🇭🇺
løst
RICE 100 Christmas Light
Type: Electric shock, Fire
Fare: The wire ends soldered to the terminals of the control unit and to the lamps are…
for 10 år siden
Se mere →
Mellem risiko
🇪🇸
løst
TRISTAR — Electric Heater (Fan)
Type: Electric shock
Fare: The user can access live parts through openings in the housing.
The product d…
for 10 år siden
Se mere →
Alvorlig risiko
🇬🇧
løst
Travel Universal Adaptor
Type: Electric shock
Fare: The adaptor has no provision for earthing and internal contacts are not secured…
for 10 år siden
Se mere →
Alvorlig risiko
🇪🇸
🇱🇺
løst
GOLD EAGLE KING — Hot Melt Glue Gun
Type: Fire
Fare: The conductors in the cable are too thin and the cable can overheat which might…
for 10 år siden
Se mere →
Alvorlig risiko
🇫🇷
løst
Immersion Heater for Trip in Cars or Trucks
Type: Fire
Fare: The product overheats which may start a fire
The product does not comply with…
for 10 år siden
Se mere →
Alvorlig risiko
🇨🇾
løst
Otto — Drink Mixer
Type: Fire
Fare: If the mixer is used to prepare a large number of drinks within a very short tim…
for 10 år siden
Se mere →
Mellem risiko
🇪🇸
🇭🇷
løst
GERIMPORT — Reading Lamp
Type: Burns, Electric shock
Fare: The screws securing the internal and external covers are inadequate and the wiri…
for 10 år siden
Se mere →
Alvorlig risiko
🇫🇮
🇩🇰
løst
Biltema — Lampunkanta-adapteri GU10 / E27, Lampunkanta-adapteri E14 / E27
Type: Electric shock
Fare: When a lamp is inserted or removed, the live cap of the lamp is accessible.
T…
for 10 år siden
Se mere →
Alvorlig risiko
🇨🇾
løst
gruppe — Unknown
Type: Burns
Fare: In the event that the product is operated beyond a certain time, the pot could o…
for 10 år siden
Se mere →
Alvorlig risiko
🇭🇺
løst
STRAUS AUSTRIA — Screw Submersible Pump/ Mélykútszivattyú
Type: Electric shock
Fare: The product cover is not earthed and the pump is equipped with supply cables tha…
for 10 år siden
Se mere →
Alvorlig risiko
🇭🇺
løst
Best — 240 LED JÉGCSAP VILÁGIT
Type: Electric shock, Fire
Fare: The cross-sectional area of the external and internal wires is too small and the…
for 10 år siden
Se mere →
Alvorlig risiko
🇭🇺
løst
delight — EU Plug Converter / Hálózati átalakító dugó
Type: Electric shock
Fare: Single-pole insertion of a plug is possible, leaving the free remaining live pin…
for 10 år siden
Se mere →
Alvorlig risiko
🇨🇾
🇬🇷
løst
KANGFU — Primo
Type: Electric shock
Fare: The plastic cover can overheat and deform making live parts accessible which the…
for 10 år siden
Se mere →
Mellem risiko
🇩🇪
løst
Decoration Light
Type: Electric shock
Fare: The mains plug does not have sufficient plug pin insulation. Contact with the li…
for 10 år siden
Se mere →
Alvorlig risiko
🇭🇺
løst
unknown — 1. 100LED Christmas Light; 2. 240LED Christmas Light
Type: Electric shock, Fire
Fare: The cross-sectional area of the external and internal wires is too small and the…
for 10 år siden
Se mere →
Alvorlig risiko
🇭🇺
løst
100L RICE LIGHTS
Type: Electric shock, Fire
Fare: The wire ends soldered to the terminals of the control unit and to the lamps are…
for 10 år siden
Se mere →
Alvorlig risiko
🇩🇪
løst
Showlite SN-400
Type: Electric shock
Fare: The remote-control socket outlet on the fog machine is of the type used for the…
for 10 år siden
Se mere →
Alvorlig risiko
🇪🇸
løst
PRIMERA — Unknown
Type: Electric shock
Fare: Live parts of the socket are accessible.
The product does not comply with the…
for 10 år siden
Se mere →
Andre kategorier
Other
(19,512)
Fruits & vegetables
(9,320)
Processed foods
(8,992)
Feed & pet food
(6,964)
Toys
(6,410)
Meat & poultry
(5,846)
Cosmetics
(5,341)
Motor vehicles
(4,759)
Nuts & seeds
(4,725)
Fish & seafood
(4,125)
Cereals & bakery
(2,877)
Herbs & spices
(2,634)
Confectionery & sweets
(2,569)
Clothing & textiles
(2,461)
Dairy & eggs
(1,881)
Beverages
(1,776)
Food-contact materials
(1,699)
Jewellery
(1,032)
Childcare articles
(959)
Protective equipment
(745)
Sports & hobby
(651)
Medicine shortage
(579)
Machinery
(575)
Furniture & decor
(418)
Pyrotechnic & lighters
(409)
Kitchen & cooking
(168)