Hazard: The engine may fail to start while driving or at a stop, due to inappropriate failure detection logic of the Powertrain Control Module (PCM). Moreover, if the engine is restarted (“push button start” is pressed) in a short period (approx. 8 seconds) after IG OFF, the relay circuit of Mild Hybrid battery may not be connected due to inappropriate start-up instructions from PCM. The fail-safe may activate, making the shift position secured in “N” range, and the vehicle may result in “impossible to drive” condition. In addition, the images of the front-, side-, and rear-view cameras may no longer appear on the centre display monitor due to improper processing logic in the view monitor camera control module. Loss of camera images when in reverse and/or using the 360° monitor can increase the risk of an accident.
⚖️ Akce nařízené orgány
- ▸ Measures ordered by economic operators (to: Distributor) Recall of the product from end users
What is this? Mazda has recalled some CX-60 cars. The engine may not start while driving or at a stop. The car’s computer (PCM) has a problem that can cause this.
What's happening? Some Mazda CX-60 cars have a fault in the engine control system. This can make the car stall or not start again after turning it off. The cameras may also stop working.
Does this affect me? This affects Mazda CX-60 cars in Portugal, Denmark, France, Poland, Sweden, and Slovakia.
What should I do? Take your car to a Mazda dealer for a free repair. Ask your dealer or Mazda for more help.
🤖 Tento souhrn v jednoduchém jazyce byl automaticky vytvořen z oficiálního oznámení agentury pomocí AI. Slouží pouze pro obecné informace — nikoli jako lékařská rada. Při rozhodování o svém zdraví se vždy poraďte s lékárníkem či lékařem a přečtěte si oficiální zdroj uvedený níže.
🔬 Lékařské / technické podrobnosti (pro profesionály)
Risk level: Serious risk · Type: Injuries · Category: Motor vehicles · Hazard: The engine may fail to start while driving or at a stop, due to inappropriate failure detection logic of the Powertrain Control Module (PCM). Moreover, if the engine is restarted (“push button start” is pressed) in a short period (approx. 8 seconds) after IG OFF, the relay circuit of Mild Hybrid battery may not be connected due to inappropriate start-up instructions from PCM. The fail-safe may activate, making the shift position secured in “N” range, and the vehicle may result in “impossible to drive” condition. In addition, the images of the front-, side-, and rear-view cameras may no longer appear on the centre display monitor due to improper processing logic in the view monitor camera control module. Loss of camera images when in reverse and/or using the 360° monitor can increase the risk of an accident. · Origin: Japan