SPAX — Betonschraube Kopfformen HS, SK, RK, RKG, IG, AG
Concrete screw advertised as approved according to ETA-20/0884 for use as a multiple fastening for non-load-bearing systems in concrete.
- Risk level
- Serious risk
- Type
- Injuries
- Kategori
- Construction products
- Fare
- The concrete screws for use as multiple fasteners in non-load-bearing redundant systems can spontaneously fail due to hydrogen embrittlement. The weight they support is transferred to adjacent screws, which have the same potential defect and can also break. A zipper effect and thus a system failure must be expected. People can be injured by falling parts.
- Origin
- Germany
⚖️ Handlinger bestilt af myndigheder
- ▸ Measures ordered by economic operators (to: Manufacturer) Stop of sales
- ▸ Measures ordered by economic operators (to: Manufacturer) Recall of the product from end users
- ▸ Measures ordered by economic operators (to: Manufacturer) Warning consumers of the risks
- ▸ Measures ordered by economic operators (to: Manufacturer) Withdrawal of the product from market
What is this? These are metal screws used to hold light things to concrete walls. They can suddenly break without warning.
What's happening? Some batches of these screws may crack under stress. If one fails, others may fail too. This can cause things to fall.
Does this affect me? If you have these screws in Germany or France, check if they are part of a light, non-load-bearing system.
What should I do? Stop using them and ask a builder or hardware store for safe replacements. Talk to your pharmacist or doctor if you are unsure.
🤖 Denne letforståelige oversigt er automatisk genereret ud fra den officielle meddelelse fra myndigheden ved hjælp af AI. Den er udelukkende til generel information — ikke medicinsk rådgivning. Vedrørende beslutninger om din sundhed, skal du altid konsultere en farmaceut eller læge og læse den officielle kilde, der er linket nedenfor.
🔬 Medicinske/tekniske detaljer Til fagfolk
Risk level: Serious risk · Type: Injuries · Category: Construction products · Hazard: The concrete screws for use as multiple fasteners in non-load-bearing redundant systems can spontaneously fail due to hydrogen embrittlement. The weight they support is transferred to adjacent screws, which have the same potential defect and can also break. A zipper effect and thus a system failure must be expected. People can be injured by falling parts. · Origin: Germany
Alle oplysninger på denne side stammer fra den officielle meddelelse fra myndighederne. Vi oversætter og opsummerer den; vi tilføjer eller redigerer ikke fakta.