⚠ Hazard
Electric shock
Across channels:
🧸 Products · 2,110
Serious risk
🇫🇮
resolved
V-tech — Car charger
Type: Electric shock
Hazard: The insulation is insufficient due to components bridging required reinforced an…
1 year ago
See more →
Serious risk
🇫🇮
resolved
Marvêlle — USB charger
Type: Electric shock
Hazard: The creepage distance between the live primary and accessible secondary circuit…
1 year ago
See more →
Medium risk
UNITED KINGDOM IN RESPEC
🇱🇺
resolved
Pro-Wax 100
Type: Electric shock, Fire
Hazard: The product mains plug is not fitted with an adequate fuse link. Should an elect…
1 year ago
See more →
Serious risk
🇫🇷
🇮🇪
resolved
CHENGRUI — Super Sun UV/LED Nail Lamp
Type: Electric shock
Hazard: The capacitors used as protective impedance between the primary circuit and the…
1 year ago
See more →
Serious risk
UNITED KINGDOM IN RESPEC
resolved
Wax Warmer for Beauty Care US
Type: Electric shock
Hazard: As the product is not properly earthed, the insulation can break down during use…
1 year ago
See more →
Serious risk
🇫🇷
🇸🇮
🇸🇰
resolved
EATON — Protection Box
Type: Electric shock
Hazard: A conductor is not sufficiently secured and if loosened, the creepage distances…
1 year ago
See more →
Serious risk
🇫🇷
🇦🇹
🇮🇪
🇸🇰
resolved
BQ V3
Type: Electric shock
Hazard: The capacitors used as protective impedance between the primary circuit and the…
1 year ago
See more →
Serious risk
THE NETHERLANDS
🇦🇹
🇮🇪
🇵🇱
🇸🇮
resolved
Antari — Fog Machine
Type: Electric shock
Hazard: The user can have access to live parts and receive an electric shock, as the pha…
1 year ago
See more →
Serious risk
🇵🇱
resolved
Anlux — LED light
Type: Electric shock
Hazard: The insulation of the light is inadequate, making live parts accessible. The use…
1 year ago
See more →
Serious risk
UNITED KINGDOM IN RESPEC
resolved
Wax warmer
Type: Electric shock
Hazard: The product is inadequately earthed and the insulation can break down during nor…
1 year ago
See more →
Serious risk
🇭🇺
resolved
Merry Christmas! 100 RICE LIGHT
Type: Electric shock
Hazard: The cable is not properly anchored (missing cable strain relief) and the accessi…
1 year ago
See more →
Medium risk
🇭🇷
resolved
HLEDL 300
Type: Electric shock
Hazard: The product has inadequate insulation. Live parts may become accessible, a user…
1 year ago
See more →
Serious risk
🇭🇺
resolved
GW — Foldable Hair Dryer
Type: Electric shock
Hazard: The cable is not properly anchored and the accessible wires have inadequate insu…
1 year ago
See more →
Serious risk
🇭🇺
resolved
XWATT — Karácsonyi fény / Christmas light
Type: Electric shock
Hazard: The cable is not securely anchored (missing cable strain relief) and has inadequ…
1 year ago
See more →
Serious risk
🇩🇰
resolved
Home automatic cartoon small baking cake bread
Type: Electric shock
Hazard: The clearance and creepage distance between the primary and accessible secondary…
1 year ago
See more →
Serious risk
UNITED KINGDOM IN RESPEC
resolved
ELPINE — Plug-In Heater
Type: Electric shock
Hazard: The heating element can be accessed with minimal force, leading to electric shoc…
1 year ago
See more →
Serious risk
🇪🇸
🇸🇮
resolved
Travel Blue — Adaptador
Type: Electric shock
Hazard: The plug of a protection class-I appliance can be inserted into the socket inten…
1 year ago
See more →
Serious risk
🇸🇰
resolved
KONDELA — Luminous Christmas tree TEMPO KONDELA
Type: Electric shock
Hazard: The product is improperly designed, with insufficient mechanical strength, an in…
1 year ago
See more →
Serious risk
🇱🇹
🇱🇻
🇵🇱
resolved
MOON — KURTINA SWIETLNA
Type: Electric shock
Hazard: The electrical insulation is inadequate. As a result, the user can receive an el…
1 year ago
See more →
Serious risk
🇪🇸
resolved
AIGOSTAR — Adaptador de 2 vías
Type: Electric shock
Hazard: The adaptor can be opened using an ordinary screwdriver without leaving it total…
1 year ago
See more →
Serious risk
UNITED KINGDOM IN RESPEC
resolved
JUSFIT — Cordless Electric Wrench
Type: Electric shock, Fire
Hazard: The clearance and creepage distance between the primary and secondary windings a…
1 year ago
See more →
Serious risk
UNITED KINGDOM IN RESPEC
resolved
JUSFIT — Cordless Reciprocating Saw
Type: Electric shock, Fire
Hazard: The clearance and creepage distance between the primary and secondary windings a…
1 year ago
See more →
Serious risk
🇫🇮
resolved
PD — USB charger
Type: Electric shock
Hazard: The insulation between the hazardous live primary parts and the accessible USB o…
1 year ago
See more →
Serious risk
🇫🇮
resolved
ARMYTEK — Rechargeable LED flashlight
Type: Electric shock
Hazard: The electrical insulation and the creepage distance between the primary and seco…
1 year ago
See more →
Serious risk
🇫🇮
resolved
Liitokala — Battery charger
Type: Electric shock
Hazard: The insulation between the hazardous live primary parts and the accessible USB o…
1 year ago
See more →
Serious risk
🇱🇹
resolved
LAMPKI CHOINKOWE LED
Type: Electric shock
Hazard: The product has inadequate insulation. The user could touch accessible live part…
1 year ago
See more →
Serious risk
UNITED KINGDOM IN RESPEC
resolved
Waizhiua — Glue gun
Type: Electric shock, Fire
Hazard: The plug pins are too close to the periphery of the plug. Users can receive an e…
1 year ago
See more →
Medium risk
🇭🇷
🇭🇺
🇸🇮
resolved
Iskra — Hair dryer
Type: Electric shock
Hazard: Due to the inadequate resistance of the thermoplastic material to heat, the mate…
1 year ago
See more →
Serious risk
🇪🇸
resolved
Luz Europa — 50-light white LED lighting chain
Type: Burns, Electric shock
Hazard: The cable of the product has an insufficient diameter, hence heating up easily a…
1 year ago
See more →
Serious risk
🇫🇮
resolved
USB charger
Type: Electric shock
Hazard: The insulation between the hazardous live primary parts and the accessible USB o…
1 year ago
See more →
Serious risk
🇩🇰
resolved
Phone chargerQualcomm Quick charger 3.0, 18W 3Amp EU-Stik Hurti
Type: Electric shock
Hazard: The adapter’s pins can easily detach from the charger. The user can receive an e…
1 year ago
See more →
Serious risk
🇫🇮
resolved
XO — USB charger
Type: Electric shock
Hazard: The insulation between the hazardous live primary parts and the accessible USB o…
1 year ago
See more →
Serious risk
🇩🇰
🇸🇮
resolved
Huawei — SuperCharge
Type: Electric shock
Hazard: The clearance/creepage distance between the primary and accessible secondary cir…
1 year ago
See more →
Serious risk
🇱🇹
resolved
IEK — Extension lead
Type: Electric shock
Hazard: The product has inadequate insulation. The user could touch accessible live part…
1 year ago
See more →
Serious risk
🇸🇰
resolved
ELGOTECH — Extension lead
Type: Electric shock
Hazard: The plug of a protection class I appliance can be inserted into the socket of an…
1 year ago
See more →
Serious risk
🇩🇪
resolved
TEMPO DI SALDI — Extension cord
Type: Electric shock
Hazard: The product does not have an earthing socket on the plug, the user is therefore…
1 year ago
See more →
Serious risk
🇸🇰
resolved
Lighting chain
Type: Electric shock
Hazard: Due to insufficient mechanical strength, inadequate nominal cross-section of the…
1 year ago
See more →
Serious risk
UNITED KINGDOM IN RESPEC
resolved
Super Fast Charging 2.0 (45W) / USB Type-C to Type-C Cable (5A)
Type: Electric shock, Fire
Hazard: The product is inadequately insulated, exposing the user to a risk of electric s…
1 year ago
See more →
Serious risk
UNITED KINGDOM IN RESPEC
🇦🇹
🇸🇮
resolved
Blackstar — Electric guitar amplifier
Type: Electric shock
Hazard: Due to an inadequate larger gap between wooden parts of the cabinet, some electr…
1 year ago
See more →
Other hazards
Pathogen / microbiological
(12,023)
Pesticide residues
(8,959)
Mycotoxins
(3,644)
Injury / mechanical
(2,697)
Labelling issues
(2,588)
Fire / burns
(1,876)
Environmental
(1,319)
Chemical risk
(1,269)
Heavy metals
(1,249)
Industrial contaminants
(1,135)
Natural toxins
(1,080)
Strangulation / suffocation
(699)
Allergens
(643)
Choking
(352)
Sight damage
(136)
Foreign bodies
(99)
Drowning
(85)
Microbiological
(73)
Hearing damage
(60)
Other