⚠ Risque
Electric shock
Sur les chaînes
🧸 Products · 2,090
Risque grave
🇸🇰
résolu
LED Decorative lights
Type: Electric shock
Risque: The mechanical strength of the control device is not sufficient, the conductors…
il y a 4 ans
Voir plus →
Risque grave
🇸🇰
résolu
LED Icicle light
Type: Electric shock
Risque: The mechanical strength of the control device is not sufficient, the conductors…
il y a 4 ans
Voir plus →
Risque grave
🇭🇺
résolu
Lighting chain
Type: Burns, Electric shock, Fire
Risque: The cable is not properly anchored and is too thin. The accessible wires have in…
il y a 4 ans
Voir plus →
Risque moyen
🇭🇺
résolu
NEW SCIENCE — USB CHARGER
Type: Electric shock
Risque: The insulation of the product is inadequate. The user could receive an electric…
il y a 4 ans
Voir plus →
Risque grave
🇫🇮
🇩🇪
🇱🇹
🇱🇻
🇵🇱
résolu
Holzmann — Single spindle vertical moulder Pöytäjyrsin
Type: Electric shock
Risque: The inductor inside the connection box touches the metal frame of the product, t…
il y a 4 ans
Voir plus →
Risque grave
🇭🇺
résolu
SOKANY — HAIR DRYER
Type: Burns, Electric shock, Fire
Risque: The hair dryer does not have a thermal cut-off device. Furthermore, the plastic…
il y a 4 ans
Voir plus →
Risque grave
🇭🇺
résolu
SOKANY — Professional Hair Dryer
Type: Burns, Electric shock, Fire
Risque: The hair dryer does not have a thermal cut-off device. The plastic material of t…
il y a 4 ans
Voir plus →
Risque grave
🇭🇺
résolu
Guangming — Professional Hair Dryer
Type: Burns, Electric shock, Fire
Risque: The hair dryer does not have a thermal cut-off device. The plastic material of t…
il y a 4 ans
Voir plus →
Risque moyen
🇭🇺
résolu
QIHANG — 3.1A 2 USB CHARGER
Type: Electric shock
Risque: The insulation of the product is inadequate. The user could receive an electric…
il y a 4 ans
Voir plus →
Risque grave
🇫🇷
résolu
2x2m 144LED Guirlande lumineuse décorative et colorée intérieur/extérieur
Type: Electric shock
Risque: The product is improperly designed, the electrical insulation is inadequate. The…
il y a 4 ans
Voir plus →
Risque grave
🇫🇷
résolu
Light string
Type: Electric shock
Risque: The product is improperly designed and has inadequate electrical insulation and…
il y a 4 ans
Voir plus →
Risque grave
🇫🇷
résolu
Guirlande de noël bandeau à rideau lumière de cordelette - 220V, 4,5M, 100LED
Type: Electric shock
Risque: The product is improperly designed, the electrical insulation is inadequate. The…
il y a 4 ans
Voir plus →
Risque grave
🇫🇷
🇮🇪
🇱🇺
résolu
Guirlande LED féerique étanche d'extérieur, 50M/400 100M/600 - CA 220V
Type: Electric shock
Risque: The electrical insulation of the external conductors, the power cable and the ca…
il y a 4 ans
Voir plus →
Risque grave
🇩🇰
résolu
Harald Nyborg A/S — Discolampe
Type: Electric shock
Risque: The cable sheath can easily break. Accessible parts (wires) can become live and…
il y a 4 ans
Voir plus →
Risque grave
🇱🇹
🇱🇻
résolu
SCHUST EL — Extension cord
Type: Burns, Electric shock, Fire
Risque: The cross-sectional area of the external and internal wires is too thin and they…
il y a 4 ans
Voir plus →
Risque grave
🇵🇱
résolu
tooLight — Oprawa oswietleniowa stala
Type: Electric shock
Risque: The electrical insulation of the luminarie is inadequate. Live parts may become…
il y a 4 ans
Voir plus →
Risque grave
THE NETHERLANDS
résolu
Kruidvat — Wereldstekker / Prise de voyage globale
Type: Electric shock
Risque: It is possible to plug one pin while the other pin is accessible. As a result, a…
il y a 4 ans
Voir plus →
Risque grave
THE NETHERLANDS
résolu
LED night-lamp with day-night sensor
Type: Electric shock
Risque: The electrical insulation is inadequate and the clearance/creepage distances bet…
il y a 4 ans
Voir plus →
Risque grave
🇵🇱
résolu
ISY — USB Travel Charger Set With Lightning Connector
Type: Burns, Electric shock, Fire
Risque: The device is not resistant to high temperatures, its casing may deform leaving…
il y a 4 ans
Voir plus →
Risque grave
🇵🇱
résolu
Electric Kettle
Type: Electric shock
Risque: The earthing protection is inadequate and the product construction is inappropri…
il y a 4 ans
Voir plus →
Risque grave
THE NETHERLANDS
résolu
Lamp socket adapter
Type: Electric shock
Risque: The screw-part of the bulb holder lacks insulation and becomes live. Consequentl…
il y a 4 ans
Voir plus →
Risque moyen
🇭🇺
résolu
QX — 240 Lights Christmas Lights
Type: Burns, Electric shock
Risque: Live parts can become accessible when the lamps are being replaced or if they br…
il y a 4 ans
Voir plus →
Risque grave
🇱🇹
résolu
BELLIGHT — Extension cord
Type: Burns, Electric shock, Fire
Risque: The cross-sectional area of the external and internal wires is too thin and this…
il y a 4 ans
Voir plus →
Risque grave
🇱🇹
🇵🇱
résolu
Art Gold — Lampki choinkowe LED Art Gold
Type: Electric shock
Risque: The cable is not properly anchored and is too thin, live parts can be easily acc…
il y a 4 ans
Voir plus →
Risque grave
🇭🇺
résolu
LAMPKI CHOINKOWE ZEWNETRZNE WEWNETRZNE
Type: Burns, Electric shock, Fire
Risque: The cable is not properly anchored and is too thin. The accessible wires have in…
il y a 4 ans
Voir plus →
Risque grave
🇱🇹
résolu
Extension cord
Type: Burns, Electric shock, Fire
Risque: The electrical insulation is inadequate. The product could overheat, leading to…
il y a 4 ans
Voir plus →
Risque grave
🇭🇺
résolu
IDEA — IDEA’S CHRISTMAS 100 LED MINILUCCIOLE
Type: Electric shock
Risque: The cable is not properly anchored. The accessible wires have inadequate insulat…
il y a 4 ans
Voir plus →
Risque grave
🇭🇺
résolu
188L LED JÉGCSAP FÉNY
Type: Burns, Electric shock, Fire
Risque: The cable is not properly anchored and is too thin. The accessible wires have in…
il y a 4 ans
Voir plus →
Risque grave
THE NETHERLANDS
résolu
PURPL Lighting — Support Tube LED
Type: Electric shock
Risque: Live parts under dangerous voltage are easily accessible, and the user could rec…
il y a 4 ans
Voir plus →
Risque grave
🇩🇪
résolu
HENGDA — Hohe Leistung Lichtnetz
Type: Burns, Electric shock, Fire
Risque: The accessible wires have inadequate insulation. Furthermore, the cable is not p…
il y a 4 ans
Voir plus →
Risque grave
🇭🇺
résolu
140 LED LIGHT
Type: Burns, Electric shock, Fire
Risque: The cable is not properly anchored and is too thin. The accessible wires have in…
il y a 4 ans
Voir plus →
Risque grave
🇭🇺
résolu
Merry Christmas 180 LED Christmas lights
Type: Burns, Electric shock, Fire
Risque: The cable is not properly anchored and is too thin. The accessible wires have in…
il y a 4 ans
Voir plus →
Risque grave
🇭🇺
résolu
140 LED Decorative Lights
Type: Burns, Electric shock, Fire
Risque: The cable is not properly anchored and is too thin. The accessible wires have in…
il y a 4 ans
Voir plus →
Risque grave
🇷🇴
résolu
RJE — Coffee heater
Type: Electric shock
Risque: The grip that insulates the connection between power supply cord and the metalli…
il y a 4 ans
Voir plus →
Risque grave
🇫🇷
résolu
ELINKUME — ELINKUME Guirlande Lumineuse Extérieure 7,65M 5W avec 25 G40 Ampoules Étanche Décoration pour ext.
Type: Electric shock
Risque: The product is improperly designed, the electrical insulation is inadequate and…
il y a 4 ans
Voir plus →
Risque grave
🇭🇷
résolu
OZCAN — Desk lamp
Type: Electric shock, Fire
Risque: The product is improperly designed and could easily overturn, while the supply c…
il y a 4 ans
Voir plus →
Risque grave
🇭🇺
résolu
100 LED LIGHT MERRY CHRISTMAS
Type: Burns, Electric shock, Fire
Risque: The cable is not properly anchored and is too thin. The accessible wires have in…
il y a 4 ans
Voir plus →
Risque grave
🇫🇮
résolu
EUROLAMP — Valonauha, LED
Type: Electric shock
Risque: The insulation of the LED control gear unit is not adequate and the clearance/cr…
il y a 4 ans
Voir plus →
Risque grave
🇵🇱
🇭🇷
résolu
LDNIO — EU Travel Charger
Type: Electric shock
Risque: The device is not resistant to high temperatures, its casing may deform leaving…
il y a 4 ans
Voir plus →
Autres dangers
Pathogen / microbiological
(12,016)
Pesticide residues
(8,959)
Mycotoxins
(3,644)
Injury / mechanical
(2,684)
Labelling issues
(2,588)
Fire / burns
(1,865)
Environmental
(1,312)
Chemical risk
(1,263)
Heavy metals
(1,249)
Industrial contaminants
(1,135)
Natural toxins
(1,079)
Strangulation / suffocation
(699)
Allergens
(643)
Choking
(351)
Sight damage
(136)
Foreign bodies
(99)
Drowning
(85)
Microbiological
(73)
Hearing damage
(60)