US UK EU DC 12 V 2A- Adaptateur d'alimentation à découpage - Adaptateur de bande lumineuse LED
Mains adaptor with power cord of 1.2 m in length and female adaptor. The product is also sold online, in particular on Wish.
- Risk level
- Serious risk
- Typ
- Electric shock
- Kategoria
- Electrical appliances and equipment
- Zagrożenie
- The clearance /creepage distances between the primary and accessible secondary circuits are not sufficient; also, these two circuits are not insulated from each other and are linked by an inadequate condenser. Furthermore, the dielectric strength (on the printed circuit and in the transformer between the primary and secondary windings) is insufficient. Consequently, the user could receive an electric shock from accessible (live) parts.
- Origin
- People's Republic of China
⚖️ Działania zlecone przez władze
- ▸ Measures ordered by economic operators (to: Other) Removal of this product listing by the online marketplace
What is this? This is a small plug-in power adapter for LED light strips. It changes household electricity to the low voltage LED strips need.
What's happening? Some of these adapters can give you an electric shock because the safe gaps and insulation between the live parts and the parts you can touch are too small.
Does this affect me? If you bought an LED strip light adapter in France, Ireland or Luxembourg, it might be one of these unsafe ones.
What should I do? Stop using the adapter right away and ask a shop or a pharmacist what to do next.
🤖 To jest automatycznie generowane streszczenie w języku prostym na podstawie oficjalnego komunikatu agencji, przy użyciu AI. Ma charakter wyłącznie informacyjny — nie stanowi porady medycznej. W kwestiach dotyczących Twojego zdrowia zawsze konsultuj się z farmaceutą lub lekarzem oraz zapoznaj się z oficjalnym źródłem zamieszczonym poniżej.
🔬 Szczegóły medyczne / techniczne dla specjalistów
Risk level: Serious risk · Type: Electric shock · Category: Electrical appliances and equipment · Hazard: The clearance /creepage distances between the primary and accessible secondary circuits are not sufficient; also, these two circuits are not insulated from each other and are linked by an inadequate condenser. Furthermore, the dielectric strength (on the printed circuit and in the transformer between the primary and secondary windings) is insufficient. Consequently, the user could receive an electric shock from accessible (live) parts. · Origin: People's Republic of China