afgesloten
LED Decorative Lights
Type: Electric shock
Gevaar: The product has inadequate insulation, and the cord extension socket allows sing…
8 maanden geleden
Bekijk meer →
Ernstig risico
🇫🇷
afgesloten
postQuam PROFESSIONAL — Fer à Boucler Cheveux Céramique Rose 23 mm 180 °C Boucleur/EBRZ
Type: Electric shock
Gevaar: The internal conductors are insufficiently affixed. As a result, they can easily…
8 maanden geleden
Bekijk meer →
Ernstig risico
🇭🇺
afgesloten
Lantern Series — Lighting chain
Type: Electric shock
Gevaar: The cable is not properly anchored, and the accessible wires have inadequate ins…
8 maanden geleden
Bekijk meer →
Ernstig risico
🇭🇺
afgesloten
200L LED LIGHTS
Type: Electric shock
Gevaar: The cable lacks proper anchoring (missing strain relief) and the accessible wire…
8 maanden geleden
Bekijk meer →
Ernstig risico
🇭🇺
afgesloten
Curtain Light, 3 M 10 HANGING
Type: Electric shock
Gevaar: The cable is not properly anchored, and the accessible wires have inadequate ins…
8 maanden geleden
Bekijk meer →
Ernstig risico
🇭🇺
afgesloten
XWATT — Karácsonyi fény, Christmas light
Type: Electric shock
Gevaar: The cable is not properly anchored, and the accessible wires have inadequate ins…
8 maanden geleden
Bekijk meer →
Ernstig risico
🇭🇺
afgesloten
YS — Merry Christmas/ Lampki Choinkowe
Type: Electric shock
Gevaar: The cable is not properly anchored, and the accessible wires have inadequate ins…
8 maanden geleden
Bekijk meer →
Ernstig risico
🇭🇺
afgesloten
Karácsonyi jégcsap égősor
Type: Electric shock
Gevaar: The product has inadequate insulation. Furthermore, the plug and socket dimensio…
8 maanden geleden
Bekijk meer →
Ernstig risico
🇭🇺
afgesloten
LED Karácsonyi égősor — NEW
Type: Electric shock
Gevaar: The cable is not properly anchored, and the accessible wires have inadequate ins…
8 maanden geleden
Bekijk meer →
Ernstig risico
🇭🇷
afgesloten
Q-X4-52
Type: Electric shock
Gevaar: The lamp can't be installed properly because the LED driver can't be inserted in…
8 maanden geleden
Bekijk meer →
Ernstig risico
🇭🇺
afgesloten
LED Merry Christmas 30 cm
Type: Electric shock
Gevaar: The product has inadequate insulation. The user could touch accessible live part…
8 maanden geleden
Bekijk meer →
Ernstig risico
🇵🇱
🇧🇬
afgesloten
Rexxer — Pompa do wody
Type: Electric shock
Gevaar: Due to inadequate grounding, insulation, cross section area of the power cord an…
8 maanden geleden
Bekijk meer →
Ernstig risico
🇭🇺
🇸🇰
afgesloten
100 LED LIGHT, Merry Christmas, 850 cm
Type: Electric shock
Gevaar: The cable is not properly anchored, and the accessible wires have inadequate ins…
8 maanden geleden
Bekijk meer →
Ernstig risico
🇭🇺
afgesloten
140 LED LIGHT, Merry Christmas, 110 cm
Type: Electric shock
Gevaar: The cable is not properly anchored, and the accessible wires have inadequate ins…
8 maanden geleden
Bekijk meer →
Ernstig risico
🇭🇺
afgesloten
188L LED fény
Type: Electric shock
Gevaar: The cable is not properly anchored, and the accessible wires have inadequate ins…
8 maanden geleden
Bekijk meer →
Ernstig risico
UNITED KINGDOM IN RESPEC
afgesloten
All-In-One — Universal Travel Adaptor
Type: Electric shock
Gevaar: The distance from the live pin to the outside edge is less than the minimum requ…
8 maanden geleden
Bekijk meer →
Ernstig risico
🇩🇪
afgesloten
28x Hexagon LED Lampe Röhren Werkstatt Garage Wand Decken Leuchte Beleuchtung DE
Type: Electric shock
Gevaar: Due to the incorrect design of the plug, the user can touch live parts and recei…
8 maanden geleden
Bekijk meer →
Ernstig risico
UNITED KINGDOM IN RESPEC
afgesloten
All-In-One — Universal Travel Adaptor
Type: Electric shock
Gevaar: The distance from the live pin to the outside edge is less than the minimum requ…
8 maanden geleden
Bekijk meer →
Ernstig risico
🇱🇹
afgesloten
LED BULB LIGHT
Type: Electric shock
Gevaar: The product has inadequate insulation. The user could touch accessible live part…
8 maanden geleden
Bekijk meer →
Ernstig risico
UNITED KINGDOM IN RESPEC
afgesloten
Henry — Quick Corded Vacuum
Type: Electric shock
Gevaar: An external screw can be in contact with live internal parts. If a user accesses…
8 maanden geleden
Bekijk meer →
Ernstig risico
🇫🇮
afgesloten
ELED — Power supply
Type: Electric shock
Gevaar: The product's insulation is inappropriate, leaving live parts accessible. The us…
8 maanden geleden
Bekijk meer →
Ernstig risico
🇵🇱
🇱🇻
🇸🇮
afgesloten
Kraft & Dele — Spawarka MMA
Type: Electric shock
Gevaar: The cross-sectional areas of the power supply and welding cables are inadequate.…
8 maanden geleden
Bekijk meer →
Ernstig risico
UNITED KINGDOM IN RESPEC
afgesloten
Jian Wang — Jian Wang Electronic Hair imp lement
Type: Electric shock, Fire
Gevaar: There is insufficient creepage and clearance distance between circuits. This can…
8 maanden geleden
Bekijk meer →
Ernstig risico
🇮🇪
UNITED KINGDOM IN RESPEC
afgesloten
TUCSON — Water circulating pump
Type: Electric shock
Gevaar: The mains electrical coupling to the pump can be connected in reverse without ap…
8 maanden geleden
Bekijk meer →
Ernstig risico
🇫🇷
afgesloten
*Archipel* — Colonne Hammam
Type: Electric shock
Gevaar: The shower booth's steam generator's transformer is too powerful. As a result, a…
8 maanden geleden
Bekijk meer →
Ernstig risico
UNITED KINGDOM IN RESPEC
afgesloten
MXBAOHENG — Chinese Medicine Pot
Type: Electric shock, Fire
Gevaar: The plug for the product lacks a fuse for protection, and therefore under fault…
8 maanden geleden
Bekijk meer →
Ernstig risico
UNITED KINGDOM IN RESPEC
afgesloten
Change Moore — Electric Pruning Shears
Type: Electric shock
Gevaar: Due to poor quality of the internal soldering and the inadequate creepage and cl…
8 maanden geleden
Bekijk meer →
Ernstig risico
🇩🇪
afgesloten
sccvee — USB Charger
Type: Electric shock
Gevaar: There is insufficient creepage and clearance distance between circuits, and it d…
9 maanden geleden
Bekijk meer →
Ernstig risico
🇵🇱
afgesloten
Heidmann — Pompa glebionowa nurek
Type: Electric shock
Gevaar: Due to inadequate grounding, insulation, cross section area of the power cord a…
9 maanden geleden
Bekijk meer →
Ernstig risico
UNITED KINGDOM IN RESPEC
afgesloten
High Speed Multi-Functional Crusher
Type: Electric shock
Gevaar: The earthing protection is inadequate.
The user could touch the accessible live…
9 maanden geleden
Bekijk meer →
Ernstig risico
🇩🇪
afgesloten
MEILEPAI — SOCKET
Type: Electric shock
Gevaar: The power supply cable has no adequate earthing system. Protection class 1 devic…
9 maanden geleden
Bekijk meer →
Ernstig risico
UNITED KINGDOM IN RESPEC
afgesloten
Electric kettle
Type: Electric shock, Fire
Gevaar: The fuse within the plug does not contain any granular filler which could lead t…
9 maanden geleden
Bekijk meer →
Ernstig risico
UNITED KINGDOM IN RESPEC
afgesloten
Power Cable 3Pin/3M
Type: Electric shock, Fire
Gevaar: The plug fuse does not contain a ballast. Its absence could lead to the plug ove…
9 maanden geleden
Bekijk meer →
Ernstig risico
UNITED KINGDOM IN RESPEC
afgesloten
SEYVUM — Pole Chain Saw
Type: Electric shock, Fire
Gevaar: Due to poor quality of the internal soldering and the inadequate creepage and cl…
9 maanden geleden
Bekijk meer →
Ernstig risico
UNITED KINGDOM IN RESPEC
afgesloten
LED Strip Lights
Type: Electric shock, Fire
Gevaar: The product is powered by an insufficient adapter as the plug is too small, the…
9 maanden geleden
Bekijk meer →
Ernstig risico
UNITED KINGDOM IN RESPEC
🇩🇪
🇱🇻
afgesloten
MXBAOHENG — MAGNETIC TUMBLER
Type: Electric shock, Fire
Gevaar: The fuse within the plug does not contain any granular filler. The filler is req…
9 maanden geleden
Bekijk meer →
Ernstig risico
UNITED KINGDOM IN RESPEC
afgesloten
MDHL — MDHL Electric Car Washing Machine
Type: Electric shock
Gevaar: The plug does not meet the dimensional requirements. The insulation may become d…
9 maanden geleden
Bekijk meer →
Ernstig risico
🇫🇮
afgesloten
Jonköping — Battery charger
Type: Electric shock
Gevaar: The product has insufficient insulation. Therefore, the user can have access to…
9 maanden geleden
Bekijk meer →
Ernstig risico
UNITED KINGDOM IN RESPEC
🇦🇹
🇩🇪
afgesloten
Travel Iron
Type: Electric shock, Fire
Gevaar: The fuse does not meet the required dimensional specifications. Under fault cond…
9 maanden geleden
Bekijk meer →
Andere gevaren
Pathogen / microbiological
(12,016)
Pesticide residues
(8,959)
Mycotoxins
(3,644)
Injury / mechanical
(2,684)
Labelling issues
(2,588)
Fire / burns
(1,865)
Environmental
(1,312)
Chemical risk
(1,263)
Heavy metals
(1,249)
Industrial contaminants
(1,135)
Natural toxins
(1,079)
Strangulation / suffocation
(699)
Allergens
(643)
Choking
(351)
Sight damage
(136)
Foreign bodies
(99)
Drowning
(85)
Microbiological
(73)
Hearing damage
(60)
Other
(15)